3.3.2 Repair procedures

To remove the expansion valve coil
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01D – 2022.02
Is the problem solved?
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 If needed, remove any parts or insulation to create more space for the
removal.
2 Remove the cap (if appliccable) from the expansion valve coil.
a Expansion valve coil cap
3 Pull up the expansion valve coil to remove it from the expansion valve body.
INFORMATION
It may be needed to turn the expansion valve coil 1/8 turn counter clockwise to
unlock it. Make sure to note the correct orientation (position) of the expansion valve
coil before removal.
b
a Expansion valve coil
Action
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"3.10 Plate
a
a
3
Components
|
4
work" [
 100].
Service manual
67