Appendices
Event name
Power Module Error
Description
An error was detected in the power module.
EtherCAT Master Function Mod-
Source
ule
Error
Level
attributes
Effects
User program Continues.
EtherCAT NET RUN
Indicators
---
System
Variable
-defined
None
variables
Assumed cause
There is a short-circuit, ground
fault, or contact failure on the U,
V, or W motor cable
There is a short-circuit on the wir-
ing of External Regeneration
Resistor or the resistance value
is small
Cause and
correction
The insulation resistance failed
between the U, V, or W motor
cable and the motor ground wire
Servo Drive failure
Attached
Attached information 1: System information
information
Precautions/
AL status code: -, Error No.: 1401 hex
Remarks
A - 118
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User's Manual (I586)
Source details
Minor fault
Recovery
Operation
EtherCAT NET ERR
---
Data type
None
Correction
Correct the connection of the U, V,
or W motor cable.
If there is a short-circuit on the wir-
ing of External Regeneration
Resistor, correct the wiring.
Replace the motor.
If this event occurs again after you
performed all corrections shown
above, replace the Servo Drive.
Event code
08390000 hex
Slave
Detection
timing
Error reset
(after cycling
Log category
slave power)
Power drive circuit is OFF
EtherCAT LINK/ACT
---
Name
None
Prevention
Confirm that the motor cables are
not broken and connect them cor-
rectly.
Wire the External Regeneration
Resistor correctly when using it.
Use the recommended External
Regeneration Resistor. If a resis-
tance value of the External Regen-
eration Resistor is small,
excessive current will flow into the
power module and cause a failure.
Confirm that the insulation resis-
tance is insulated between the U,
V, and W motor cable and the
motor ground wire before using the
motor.
Do not perform Servo ON/OFF fre-
quently. Doing so may cause a
Servo Drive failure.
Continuously