System Configuration Calling Up Parameters; (Parameters) Parameters - Viessmann Vitodens 050-W Installation And Service Instructions Manual

Table of Contents

Advertisement

Calling up parameters
Note
The display and setting of some parameters is
dependent on:
Heat generator
Connected accessories and the functions associated
with them
Tap the following buttons:
1.
and OK simultaneously for approx. 4 s, then
release.
2. Use
/
to select "b.2" for system configura-
tion.
Parameters
Note
Parameter values in bold are factory settings.
3 "Scald protection"
Setting
Off
ON
4 "Max. speed of speed-controlled primary/heating circuit pump in standard mode, heating circuit 1"
Setting
3. OK
4. Use
/
ment. See tables below.
5. OK
6.
/
for the required value.
7. OK
Note
Further parameters can be called up via the software
tool.
Explanations
The adjustable DHW temperature is limited to a maxi-
mum value.
0
Scald protection off
Danger
Risk of injury due to higher DHW temperature.
Inform the system user of the risk from the high-
er outlet temperature at the draw-off points.
1
Scald protection on (max. DHW temperature 60 °C)
Note
Even with the scald protection switched on, higher
outlet temperatures may occur at the draw-off points
in the following cases:
While the appliance is being calibrated
Explanations
Maximum speed of the internal circulation pump in
heating mode with standard room temperature
...
Delivered condition specified by settings specific to
the heat generator
0 to 100
Maximum speed adjustable from 0 to 100 %
System configuration (parameters)
to select the parameter for adjust-
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents