System Configuration Calling Up Parameters; (Parameters) Parameter - Viessmann VITODENS 100-W Installation And Service Instructions Manual

Wall mounted gas condensing boiler
Hide thumbs Also See for VITODENS 100-W:
Table of Contents

Advertisement

System configuration (parameters)
Calling up parameters
Note
The display and setting of some parameters is
dependent on:
Heat generator
Connected accessories and the functions associated
with them
Tap the following buttons:
1.
and OK simultaneously for approx. 4 s, then
release.
2. Use
/
to select "b.2" for system configura-
tion.
Parameter
Note
Parameter values in bold are factory settings.
3 "Scald protection"
Setting
Off
On
6 "Minimum heating output"
Setting
42
3. OK
4. Use
/
ment. See tables below.
5. OK
6.
/
for the required value.
7. OK
Explanations
The adjustable DHW temperature is limited to a maxi-
mum value.
0
Scald protection off
Danger
Risk of injury due to increased DHW tempera-
ture.
Inform the system user of the risk from the
raised outlet temperature at the draw-off points.
1
Scald protection on (maximum DHW temperature
60 °C)
Note
Even with the scald protection switched on, higher
outlet temperatures may occur at the draw-off points
in the following cases:
While the appliance is being calibrated
Explanations
A limit can be set on the minimum heating output for
heating mode.
...
Delivered condition specified by settings specific to
the appliance
0 to 100
Adjustable from 0 to 100 %
to select the parameter for adjust-