Vitodens 100-W, B1HE/B1KE Combi Installation/Service

Instructing the System User

Calling Up Parameters

System Configuration (parameters)
The system manufacturer must provide the operator of
the system with the operating instructions and instruct
the operator in the system operation.
This also includes all components added as accessories,
e.g. remote controls. The system installer should also
provide information on the required maintenance.
DHW hygiene
For optimum DHW hygiene, avoid DHW temperatures
that are < 122°F (50°C). For larger systems and systems
with low water exchange, the temperature should not
drop below < 140°F (60°C).
Hygiene function (B1HE only)
The DHW can be heated to a specified (higher) target
DHW temperature for a period of one hour.
To activate the function, see the operating instructions.
Inform the system user what DHW temperatures should
be set and the risks associated with having a raised outlet
temperature at the draw-off points.
Note: All parameters are accessible via a software tool,
such as the "Vitoguide mobile" app.
Parameters are split into the following groups:
– "General"
– "Boiler"
– "DHW"
Note: The display and setting of some parameters is
dependent on:
Boiler
Tap the following buttons:
1.
and OK simultaneously for approx. 4 sec, then
release.
2. Use
to select "System configuration".
3. OK
4. Use
to select the required group.
5. OK
6. Use
to select the parameter for adjustment.
See tables below.
7. OK
8.
for the required value.
9. OK