3 EtherNet/IP Connection Procedures
3
Setting Connections 2 to 16
Set connections 2 to 16 in the same
way as described above.
For each connection, change the
Exclusive Owner number and other
data from 1 to up to 16.
For the Target Variable, set the value
in increments of +4, i.e., 768 is followed
by 772 for inputs and 769 is followed by
773 for outputs.
4
Select Device Bandwidth and make
sure that the bandwidth used by the de-
vice is within the specification range of
the PMAC.
5
Click the Transfer to Controller button.
If the message shown on the right
appears, click the Yes button.
If the message shown on the right
appears, select Change to
PROGRAM mode and execute the
transfer.
6
If the message shown on the right ap-
pears after completion of transfer, click
the Yes button.
*1.
This value specifies the instance ID of the Assembly object. Refer to A-7-2 Assembly Object (Class ID: 04
Hex) in the CK3M-series Programmable Multi-Axis Controller Hardware User's Manual (Cat. No. O036) or
A-3-2 Assembly Object (Class ID: 04 Hex) in the CK3E-series Programmable Multi-Axis Controller
Hardware User's Manual (Cat. No. I610) for details.
3-12
CK3E/CK3M-series EtherNet/IP Connection Guide (O903)