Table of Contents

Advertisement

4
As shown on the right, add a variable
with the name eip_from_ppmac_01, the
data type eip_Connection, and the net-
work publish setting of Input.
Similarly, add the subsequent variables
up to eip_from_ppmac_16.
Variables are added in this way be-
cause the test program and EtherNet/IP
use 16 connections for input.
5
As shown on the right, add a variable
with the name eip_to_ppmac_01. the
data type eip_Connection, and the net-
work publishs setting of Output.
Similarly, add the subsequent variables
up to eip_to_ppmac_16.
Variables are added in this way be-
cause the test program and EtherNet/IP
use 16 connections for output.
3-2-4

Creating and Checking the User Program

Create a program for the operations check.
The operations check program uses the ST language. Refer to the NJ/NX-series CPU Unit Software
User's Manual (Cat. No. W501) for details.
1
Adding a user program (ST)
In the Multiview Explorer, right-click
Programs under Programming and select
Add – ST from the menu.
2
Selecting the user program (Program1)
In the Multiview Explorer, double-click
Program1 under Programming –
Programs.
CK3E/CK3M-series EtherNet/IP Connection Guide (O903)
3 EtherNet/IP Connection Procedures
3
3-5