2. WIRING
4. Pull out the control unit cable from the cover.
5. Pass the optional cable assy (TET-16-045A) through the grommet and cable en-
trance on the control unit.
6. Fasten the shield of the cable with the cable clamp (removed at step 2).
Note: When the serial number is "200001"
or later, fasten the shield as shown in the
figure to the right.
7. Connect the cable to the J1, then secure the cable with the wiring clamp.
8. Reattach the control unit cover.
Wiring for the processor unit
1. Unfasten four screws (M4x8) to remove the processor unit cover.
2. Unfasten three bolts to remove the cable clamp (upper) as shown below.
J11
J11
Unfasten these three bolts to remove the upper plate.
3. Disconnect the control unit cable from the processor unit, then connect the cable
assy (TET-16-045A).
4. Set the shield part of cables under the cable clamp then tighten the cable clamp.
5. Attach the processor unit cover.
2-34
J8 J8
J4
J4
J6 J6
J12 J13
J13
J12
J9 J9
J5 J5
J3 J3
J14
J14
J7 J7
J10
J10
Unfasten this bolt to use
Unfasten this bolt to use
the lower clamp holes.
the lower clamp holes.
J3 to J6: IEC 61162-1/2
J7 to J10: IEC 61162-1
J11: Alarm system (System fail, Power fail,
Normal close×2, Normal open×2, ACK IN)
J12: Main control unit
J13 and J14: Sub control units
Clamp holes (upper)
Clamp holes (lower)
Lay shields of cables
under this clamp then
tighten the clamp.