Furuno ECDIS FMD-3200 Installation Manual page 51

Electronic chart display and information system
Hide thumbs Also See for ECDIS FMD-3200:
Table of Contents

Advertisement

MC-3010A/3020D/3030D
This paragraph shows how to set the MC-ANLG Board (24P0115, for MC-3010A),
MC-DIN Board (24P0116, for MC-3020D) and MC-DOUT Board (24P0117, for MC-
3030D).
Rotary switch: Use the rotary switch (U18) to set the MODBUS address with a digit
of number from "0". When multiple sensor adapters are connected to the MC-3000S,
the same number cannot be used among them. (It is allowed to use the same number
between the MC-3000S and a sensor adapter.)
Jumper block
Use the jumper block J25 to set the termination resistor on/off for the MODBUS com-
munication on the connector J1. For the first and last sensor adapter in a series, their
termination resistors should be set to ON. If not, communication between sensor
adapters is not possible.
Jumper block J25
1-2
OPEN
2-3
SHORT
1-2
SHORT
2-3
OPEN
Connector J1
Termination resistor: OFF (default setting)
Termination resistor: ON
2. WIRING
2-31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecdis fmd-3300Ecdis fmd-3200-bb

Table of Contents