Graco Reactor 3 E-XP1 Operation page 57

Hide thumbs Also See for Reactor 3 E-XP1:
Table of Contents

Advertisement

Heater
Heater Performance
Heater
Performance Chart
Performance
140
(60)
130
(54.4)
120
(48.9)
110
(43.3)
100
(37.8)
90
(32.2)
80
(26.7)
a T in
degrees F
70
(21.1)
(degrees C)
60
(15.6)
50
(10)
40
(4.4)
30
(-1.1)
20
(-6.7)
10
(-12)
0
(-17.8)
0
0.5
(0)
(1.9)
NOTE: Heater performance data is based on testing with 20 wt. hydraulic oil and 240V across
NOTE:
NOTE:
heater power wires.
Internally Heated
Heated Hose
Hose Pressure
Internally
Internally
Heated
Hose
Internally heated hoses experience additional pressure drop when compared to externally heated
hoses of the same inner diameter. The system pressure setpoint may need to be increased to
offset the additional pressure drop and achieve desired pressure and pattern at the gun. Pressure
drop may vary based on pressure setpoint, temperature setpoints, chemical viscosities, and hose
configuration (length and number of fittings). Reference the table below as a starting point for
offsetting the additional pressure drop.
Hose Length
Hose
Hose
Length
Length
< 100 ft (30 m)
100 - 200 ft (30 - 70 m)
>200 ft (70 m)
Internally Heated
Heated Hose
Hose Temperature
Internally
Internally
Heated
Hose
Temperature setpoints may need to be adjusted on internally heated hoses to address additional
pressure imbalance caused by additional pressure drop. In order to balance pressures, increase the
temperature of the higher pressure material and decrease the temperature of the lower pressure
material. Once the imbalance is resolved, adjust the temperature setpoints up or down together to
achieve the desired results.
3A8500E
Chart
Chart
A
1
1.5
2
(3.8)
(5.7)
(7.6)
Flow Rate in gpm (lpm)
Pressure Setpoint
Setpoint Adjustment
Adjustment
Pressure
Setpoint
Adjustment
Temperature Setpoint
Setpoint Adjustment
Temperature
Setpoint
C
B
2.5
3
3.5
4
(9.5)
(11.4)
(13.2)
(15.1)
Pressure
Pressure
Pressure Setpoint
Setpoint Adjustment
Setpoint
Increase 50 - 150 psi (3.4 - 10.3 bar)
Increase 100 - 250 psi (6.9 - 17.2 bar)
Increase 150 - 350 psi (10.3 - 24.1 bar)
Adjustment
Adjustment
Performance Charts
A
Power (7kW)
B
Power (10kW)
C
Power (15kW)
4.5
(17.1)
Adjustment
Adjustment
57

Advertisement

Table of Contents
loading

Table of Contents