"SIMATIC Mobile Reader" app
5.4 Functions of the UHF app variant (RF660M)
Functions/
parameter
Format
Start (bytes)
Length (bytes)
Data to be
written
Write
60
Description
Drop-down list to select the input format of the data to be written.
DEC
Decimal input format. Numbers from 0 ... 255 are allowed.
HEX
Hexadecimal input format. Hyphens are entered automatically.
ASCII6
ASCII6 input format. All characters compliant with VDA 5500 are allowed.
ASCII8
ASCII8 input format. All ASCII characters are allowed.
Drop-down list to select the start address of the memory area in bytes from
which you want to change or write the data of the target transponder.
Maximum permissible start address: 255 bytes
Drop-down list to select the length of the memory area in bytes within which you
want to change or write the data of the target transponder.
Maximum permissible length: 63 bytes
Input box in which you can enter the data or the text that you want to write to
the selected memory area of the target transponder.
Note: Note that it is possible in principle to enter in this box data of a length that
differs from the information in the "Length (bytes)" box.
If less data is entered than specified in the "Length (bytes)" box and you click the
"Write" button, this data is written. All other data is retained.
If more data is entered than specified in the "Length (bytes)" box, it is highlighted
in color. In this case, the data cannot be written.
Button to execute the write operation
Mobile reader SIMATIC RF360M/RF660M