Mr. Heater MHVFBI10LPT Operating Instructions And Owner's Manual

Unvented lp-gas fired buddy wall-mount heater

Advertisement

Available languages

Available languages

Quick Links

Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
read InsTruCTIOns CareFullY: Read and follow all instructions. Place instructions in a safe
place for future reference. Do not allow anyone who has not read these instructions to assemble,
light, adjust or operate the heater.
UNVENTED LP-GAS FIRED
BUDDY WALL-MOUNT HEATER
lanGuaGes
ENGLISH
Pages E1 — E16
SPANISH
Pages S1 — S16
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Shut off gas supply
• Do not try to light any appliance
• Do not touch an electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion and
Ventilation section on page 4 of this manual.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to this manual for correct installation and operational procedures. For assistance or additional
information consult a qualified installer, service agency, or gas supplier.
Unvented Liquid Propane Fired Room Heater
OpErating instructiOns
and Owner's Manual
Mr. Heater, INC., 4560 W. 160
E1
TH
ST., CLEVELAND, OHIO 44135 · 800-251-0001
Installation Instructions and Owner's Manual
Model #
MHVFBI10LPT
For model serial numbers, see page E16.
04/13 55121 Rev13A

Advertisement

Table of Contents
loading

Summary of Contents for Mr. Heater MHVFBI10LPT

  • Page 1 Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or gas supplier. Mr. Heater, INC., 4560 W. 160 ST., CLEVELAND, OHIO 44135 · 800-251-0001 04/13 55121 Rev13A Unvented Liquid Propane Fired Room Heater Installation Instructions and Owner’s Manual...
  • Page 2: Table Of Contents

    This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with any other gas. *Aftermarket completion of sale, not for the purpose of resale, from the manufacturer.
  • Page 3: Specifications

    Fabric / flammable objects 36” (915cm) 36” (915cm) PRECAUTIONS: DANGER: Carbon monoxide poisoning may lead to 1. MHVFBI10LPT may be installed in a bedroom, but death. not a bathroom, or any place where a strong wind Carbon Monoxide Poisoning: would shut down the appliance.
  • Page 4: Thermostatic Control

    SAFETY DEVICE b. Whether stripping has been added on openable win- dows and doors, and This heater has a pilot with an Oxygen Depletion Sen- sor (ODS) safety shut off system. The ODS/pilot shuts c. Caulking or sealants are applied to areas such as off the heater if there is not enough fresh air.
  • Page 5: Installation

    heater, Gas furnace, Vented gas heater, Gas fire- place logs, and Other gas appliances* *Do not include direct-vent gas appliances. Direct- vent draws combustion air from the outdoors and 12” vents to the outdoors. Example: Or remove Ventilation Gills into Ad- Gas water heater 40,000 Btu/hr Ventilation...
  • Page 6: Fastening Heater To Wall

    WARNING: A qualified service person must install For convenience and efficiency, install the heater: heater. Follow all local codes. • Where there is easy access for operation, inspection, and service. CHECK GAS TYPE Use only LP-gas. If your gas supply is not LP-gas, do •...
  • Page 7 1. Attach to wall studs 3. Insert mounting screws through bracket and into wall studs. 2. Attach to wall anchor 4. Tighten screws until mounting bracket is firmly fastened to wall studs. Attaching to Wall using Anchor: For attaching mounting bracket to hollow walls (wall ar- eas between studs) or solid walls (concrete or masonry) Note: Wall anchors, mounting screws, and spacer are in hardware package.
  • Page 8: Floor Mounting Away From Wall

    location, heater may be locked into position us- ing anchoring holes in mounting feet. Screw Screw Note: Use of floor mounting feet will require you to hole hole use a 3/8 NPT street elbow to make gas connec- tion. Figure 10 CONNECTING TO GAS SUPPLY 2.
  • Page 9 1. Close equipment shutoff valve (see figure 13). 2. Pressurize supply piping system by either using Pressure Regulator compressed air or opening propne/LP supply valve. 3. Check all joints from the propane/LP supply valve to equipment shutoff valve (see figure 3/8”...
  • Page 10: Operating Your Heater

    8. Turn off heater (see To Turn OFF Gas to Appli- be depressed for about 30 seconds. This will allow ance, page 10. air to bleed from the gas system. 9. Replace lower front panel. 6. Push in control knob and rotate control knob back to OFF position then rotate counterclock- OPERATING YOUR HEATER wise to PILOT/IGN position.
  • Page 11: Cleaning And Maintenance

    INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 21 show a correct pilot flame pattern. Figure 22 shows an incorrect pilot flame pattern. The incorrect pilot flame pattern is not touching thermocouple. This will cause the thermocouple to cool.
  • Page 12: Troubleshooting

    TROUBLESHOOTING NOTE: All troubleshooting items are listed in order of operation and likely occurrence. WARNING: Only a qualified service person should service and repair heater. CAUTION: Never use a wire needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Make sure grille guard is in place before running heater.
  • Page 13 OBSERVED SYMPTOM POSSIBLE CAUSE REMEDY Heater shuts off in use (ODS operates) 1. Not enough fresh air is available 1. Open window and/or door for ventilation 2. Low line pressure 2. Contact local gas company 3. ODS/pilot is partially clogged 3.
  • Page 14: Exploded-View Parts Drawing

    Unvented Liquid Propane Fired Room Heater Installation Instructions and Owner’s Manual...
  • Page 15: Parts List

    70828 Unvented Liquid Propane Fired Room Heater Installation Instructions and Owner’s Manual...
  • Page 16: Warranty

    Mr. Heater, Inc. warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase. Mr. Heater, Inc. will repair or replace this product free of charge if it has been proven to be defective within the 1-year period, and is returned at customer expense with proof of purchase to Mr.
  • Page 17 Instalador: deje este manual junto con el artefacto. Consumidor: Conserve este manual para referencia futura. InsTruCCIOnes de InsTalaCIÓn Y Manual del usuarIO Mr. HeaTer lea CuIdadOsaMenTe las InsTruCCIOnes: Lea y siga todas las instrucciones. Conserve estas instrucciones en un lugar seguro para futura referencia.
  • Page 18 Este artefacto puede ser instalado en una casa (móvil) del mercado de postventa* fabricada de manera permanente, si no estuviese prohibido por las normas locales. Este artefacto sólo se debe usar con el tipo de gas indicado en la placa de especificación. Este artefacto no se debe convertir para usarlo con otro tipo de gas.
  • Page 19 esTaBleCIendO una VenTIlaCIÓn Características del producto aDEcuaDa Los dados a continuación son párrafos de las Normas nacionales de gas combustible (National Fuel Gas Code), NFPA 54/ANSI Z223.1, Artículo 5.3, Aire para combustión y ventilación . Todos los espacios del hogar recaen dentro de una de estas tres clasificaciones de Perilla de control Control Knob ventilación:...
  • Page 20 nota: el espacio incluye el cuarto en donde instaló el calentador Ventilación desde el interior de la edificación y los cuartos contiguos que tienen pasillos sin puertas o rejillas El aire fresco provendrá de un espacio abierto contiguo. de ventilación entre ellos. Cuando se ventile a un espacio abierto contiguo, debe colocar Obtenga el volumen del espacio multiplicando largo x ancho x dos aberturas permanentes: una a 30 cm (12 pulgadas) del...
  • Page 21 Ventilación del exterior uBICaCIÓn del CalenTadOr Si fuera necesario permita la entrada de aire fresco adicional haciendo Este calentador está diseñado para ser montado sobre la pared. uso de conductos o rejillas de ventilación. Conecte estos artículos Para su comodidad y eficiencia, instale el calentador: directamente al exterior o a espacios abiertos al exterior.
  • Page 22 16,5 cm (6-1/2") Mín. 10.000 BTu MOnTaJe del CalenTadOr a la Pared 6-1/2” Min. 10,000 BTU soporte de montaje El soporte de montaje está ubicado en el panel trasero del calentador (remítase a la figura 5). Se ha colocado ahí con cinta adhesiva para su envío.
  • Page 23 Cómo colocar el calentador sobre el soporte de montaje CuIdadO: Nunca conecte el calentador directamente al suministro Ubique dos ranuras horizontales en el panel trasero del de Propano. Este calentador requiere de un regulador externo (no suministrado). Instale el regulador externo entre el calentador y el calentador (remítase a la figura 9).
  • Page 24 Desconecte el artefacto con su válvula de gas principal las mangueras Mr. Heater suministradas (remítase a la lista de (válvula de control) y válvula de cierre del sistema de tubería piezas).
  • Page 25 Open abierto estado bajo el agua. instrucciOnEs DE EncEnDiDO ¡deTÉnGase! Lea toda la información de seguridad incluida con del calentador y la del costado del mismo. Verifique que el suministro de gas al calentador esté abierto. Válvula de Equipment cerrado Closed cierre del Gire la perilla de control de gas en sentido horario hasta la...
  • Page 26 el calentador se apagará. Si el patrón de la llama del piloto es Botón de encendido incorrecto, como se muestra en la Figura 22: Ignitor Button perilla de control Control Knob • Apague el calentador (remítase a Cómo cerrar el gas hacia el artefacto , página 1 1 para los modelos que no tienen termostato).
  • Page 27 EspEciFicaciOnEs Asegúrese de que la rejilla de protección esté en su lugar antes de encender el calentador. Si se saca la pantalla o rejilla de protección para su mantenimiento, la misma se debe volver a colocar antes de BTU (Disponible) MHVFB10LP poner el calentador en funcionamiento.
  • Page 28 resOluCIÓn de PrOBleMas nOTa: Todos los problemas están enumerados en orden de operación y posibilidad de que ocurran. adVerTenCIa: Sólo un técnico de mantenimiento calificado debe realizar el mantenimiento y reparar el calentador. CuIdadO: Nunca use una aguja de metal u objeto similar para limpiar el SDO/piloto. Esto puede dañar el SDO/piloto. Asegúrese de que la rejilla de protección esté...
  • Page 29 El quemador no se enciende cuando el SDO/ El orificio del quemador está obstruido. Limpie el orificio del quemador (remítase El diámetro del orificio del quemador es piloto está encendido. a Limpieza y mantenimiento, página 1 1), demasiado pequeño. o reemplace el orificio del quemador. La presión del gas de entrada de es muy Reemplace el orificio del quemador.
  • Page 30 En caso de que tenga más dudas sobre la instalación, el uso o la resolución de problemas, llame al número 800 de Enerco Group, Inc. que aparece en la parte de atrás de este manual. accEsOriOs CalenTadOr a lP-Gas sIn VenTIlaCIÓn • Modelo MHVFBI10lPT UNVENTED LP-GAS FIRED HEATER Model MHVFBI10LPT HSVFB10LPT...
  • Page 31 CalenTadOr MOnTadO a la Pared, a Gas lP, sIn VenTIlaCIÓn ARTÍCULO NÚMERO DE PIEZA DESCRIPCIÓN CANT. 70300 Gabinete 70833 Panel superior del gabinete 70592 Panel derecho del gabinete 70593 Panel trasero del gabinete 70591 Panel izquierdo del gabinete 70594 Panel delantero inferior 70312 Reflector 70319...
  • Page 32 Mr. Heater, Inc. reparará o reemplazará este producto en forma gratuita si se comprueba que tiene un defecto de fábrica dentro del año de garantía, y si se devuelve a Mr. Heater, Inc. dentro del período de la garantía, debiendo el cliente hacerse cargo de los gastos de devolución.