Intrinsically Safe Marking
2460
Substitution of components may impair suitability for intrinsic safety. Replace batteries only in
non-hazardous locations.
To prevent ignition of flammable or combustible atmospheres, disconnect power before
servicing.
Hazardous Areas Classified By Zones
Mesh Router is intended to be used in hazardous areas or mines susceptible to firedamp
classified  zone 0, zone 1 or zone 2, within the temperature range of -40º C to +50º C, where
gases of explosion groups IIA, IIB or IIC and T4 may be present.
Hazardous Areas Classified By Divisions
Mesh Router is  intended to be used in hazardous areas classified for Class I Div. 1 or 2, within
the temperature range of -40º C to +50º C, where gases of explosion groups A, B, C or D and
temperature class T4 may be present.
Instruction For Safe Use
Strictly follow the instructions for safe use. Application of the Mesh Router requires full
understanding and strict observation of the instructions.
Mesh Router
Cl. I, Div. 1, Gr A, B, C, D T4
Ta = -40° C to +50° C
IECEx SIR 18.0066X
Sira 18ATEX2251X
II Ex ia IIC T4 Ga
IM1 Ex ia I Ma
Ui = 3.6V, Ci=78µF, Li/Ri=3.5µH/ohm
WARNING!
WARNING!
8
User Manual