Is the antenna is attached?
l
Does the Pan ID match the network you want to join?
l
Does the Channel match the channel on which the other instruments are
l
operating?
Are the other instruments turned on and within range?
l
Did you change the Pan ID or Channel? If so, restart the instrument.
l

Turning the Mesh Router Host Off

Hold down the [MODE] key through the "5...4...3... 2... 1... Power Off" sequence. The Mesh
Router is off when the display is blank. Release the [MODE] key.
The Mesh Router is off when the display is blank.

Battery Indicator

The Mesh Router's internal battery is designed to provide power for up to 10 days. When
the battery gets low, the Mesh Router beeps once per minute and the battery icon is
empty. It is recommended that the battery be changed immediately, to minimize
disruption.
Battery power is indicated by "B:" followed by a number and a percent sign. For example,
B: 100%.
The battery should be replaced before it is completely discharged. See page See "Internal
Battery Replacement" on page 53 for more information. for the replacement procedure.
When the battery is completely depleted, the LCD displays "Power off." and the LED and
buzzer alarm activate once per second. The Mesh Router shuts down after you press any
key, or shuts down automatically if you do not press a key for 60 seconds.
Note:For a fixed-system application, an external power source, the Honeywell PowerPak,
can be used as a substitute for the internal battery. Only remove the external battery
adapter in non-hazardous locations.