Cisco Catalyst IE9300 Hardware Installation Manual page 88

Table of Contents

Advertisement

Switch Specifications
Measure
Relative humidity
Operating altitude
Storage altitude
Thermal spacing
Operational shock
Nonoperational shock
Note
The safety certifications apply only to ambient temperatures under 140 F (60 C).
Table 22: Switch Power Requirements
Measure
Nominal input voltage
Supported input voltage operating range
Cisco Catalyst IE9300 Rugged Series Switch Hardware Installation Guide
80
Range
5 percent to 95 percent noncondensing
• Up to 15,000 feet (4572 m) with no temperature derating
• Up to 40,000 feet (12,192 m) with temperature derating down to
25° C
Up to 40,000 feet (12,192 m)
1.75 in (4.4 cm) clearance top, sides, and bottom
50G at 11ms, half sine and 200G ar 2.11ms, half sine
65 to 80G at 9ms, trapezoidal
Requirement
• PWR-RGD-AC-DC-H:
100 to 240 VAC, 50 to 60 Hz
100 to 250 VDC
• PWR-RGD-AC-DC-250:
100 to 240 VAC, 50 to 60 Hz
100 to 250 VDC
• PWR-RGD-LOW-DC-H:
4 to 60 VDC
• PWR-RGD-AC-DC-H:
90 to 264 VAC, 50 to 60 Hz
90 to 300 VDC
• PWR-RGD-AC-DC-250:
90 to 264 VAC, 50 to 60 Hz
90 to 300 VDC
• PWR-RGD-LOW-DC-H:
18 to 75 VDC
Technical Specifications