Wire The Power Source - Cisco Catalyst IE9300 Hardware Installation Manual

Table of Contents

Advertisement

Power Supply Installation
Figure 24: Removing the Power-Supply Blank
Step 3
Insert the power-supply module into the slot and gently push it in, as shown in the following illustration.
Figure 25: Insert the Power-Supply Module
When correctly inserted, the PWR-RGD-LOW-DC-H or PWR-RGD-AC-DC-H power supply is flush with the switch
rear panel. The PWR-RGD-AC-DC-250 extends 30 mm from the rear of the switch.
Step 4
Use a ratcheting torque screwdriver to torque each screw to 8-14 in-lb.
Step 5
If desired, repeat the preceding steps to add a second power supply.

Wire the Power Source

Before you begin
Review the following warnings:
Warning
Warning
Warning
This product relies on the building installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: AC: 10 A, DC: 15 A. Statement 1005
A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement
1022
Only trained and qualified personnel should be allowed to install or replace this equipment. Statement
1030
Cisco Catalyst IE9300 Rugged Series Switch Hardware Installation Guide
Wire the Power Source
43