Power Supply Installation
Step 3
Use the appropriate copper wire to connect from the power-input terminal to the power source.
Step 4
Strip each of the two wires to 0.25 inch (6.3 mm) ± 0.02 inch (0.5 mm), as shown in the following illustration.
Do not strip more than 0.27 inch (6.8 mm) of insulation from the wire. Stripping more than the recommended
Note
amount of wire can leave exposed wire from the connector after installation.
Figure 27: Stripping the Input Power Source Wire
Step 5
Insert the wire into a spade terminal, and crimp it to the wire, as shown in the following illustration.
You can also use a ring or flanged spade terminal as listed in
Figure 28: Crimping the Spade Terminal Lug
Step 6
Loosen the terminal screw, and slide the terminal under the screw and washer.
Use the appropriate terminal screws based on power supply type: high-voltage (AC or DC) or low-voltage
Note
(DC).
Step 7
Make the power connection, following the instructions appropriate to your connection:
• AC Power Connection: Connect the line wire into the terminal screw labeled L and the neutral wire into the terminal
screw labeled N to complete the AC connection, as shown in the following illustration.
Figure 29: Connecting the Wires to the High-Voltage AC Power (PSU1)
• DC Power Connection: Connect the positive wire into the terminal screw labeled " +", and the negative wire into
the terminal screw labeled " – ".
• Low-voltage DC Power-Supply Module: Connect the wires to the terminals labeled "Lo."
• High-voltage DC Power-Supply Module: Connect the wires to the terminals labeled "Hi," as shown in the following
illustration.
Required Tools and Equipment, on page
Cisco Catalyst IE9300 Rugged Series Switch Hardware Installation Guide
Wire the Power Source
39.
45