Technical data
11.10 Certificates and approvals
Table 11-17
Description
Cleaning method
11.8
Process variables FCT010
Description
Primary process variables
Derived process variable
11.9
Approvals note
Note
Device-specific approvals
Always refer to nameplates on the device for device-specific approvals.
11.10
Certificates and approvals
FCT010 (can be installed in Zone 1 for gas and Zone 20/21 for dust)
"Intrinsic safety" type of protection
ATEX/IECEx
Sira 17ATEX1215X
Pressure equipment
114
Cleaning and sterilizing conditions
Specification
•
CIP
•
SIP
Specification
•
Mass flow
•
Density
•
Medium temperature
•
Volume flow
II 2(1) G
II 1 (1) D
II 2(1) D)
Ex db ia [ia Ga] IIC T6 Gb
Ex db [ia Ga] IIC T6 Gb
Ex ia [ia] IIIC T85°C Da
Ex tb [ia Da] IIIC T85°C Db
Tamb = -20°C to +60°C
•
2014/68/EU Pressure Equipment Directive (PED)
•
Canadian Registration Number (CRN)
SITRANS MASS 2100 & FC300 (FCT010/DSL)
Operating Instructions, 06/2020, A5E39788682-AB