Aligning and configuring
7.2 Configuring antennas
Procedure
Follow these steps to configure the antennas of the top read point (Readpoint_1):
1. Position two objects on the conveyor system in such a way that the front object passes
through the light barrier while the rear object maintains the minimum distance to the front
object.
When positioning, make sure that the transponders of the objects are at the top and
opposite each other.
Figure 7-2
2. Open the WBM of the reader and switch to the menu "Diagnostics > Tag monitor".
3. In the "Basic settings", select the read point "Readpoint_1" and the antenna ① and start the
"Continuous acquisition".
4. Select the transponder of the object that is currently in the antenna field from the
transponder list.