Commissioning
Select display P9. P9 flashes.
Press the ENTER key. OFF flashes.
Use the keys to select ON. ON flashes.
Press the ENTER key. Display DC flashes.
NOTE
Display DC/AC stands for the control signal of the
central control device. Either DC or AC must be se-
lected depending on the type used.
Selecting the DC control signal
Use the keys to select DC. Display flashes.
Press the ENTER key. WSG appears. OFF flashes.
NOTE
Only for operation on the central control unit ZWU
06E: If the usage area "WSG Intelligent" was selected
(see standard display), switch to WSG ON (ON
flashes).
Selecting the AC control signal
Use the keys to select AC. Display flashes.
Press the ENTER key. Display 80 flashes.
NOTE
Display AC 80 stands for the maximum control signal
duty cycle (duty cycle signal) of the central control de-
vice.
In special cases, e.g. extremely old systems, the duty
cycle signal may need to be adjusted.
If necessary, adjust the duty cycle signal with the
keys.
Press the ENTER key. WSG appears. OFF flashes.
NOTE
Only for operation on the central control unit ZWU 06E:
If the usage area "WSG Intelligent" was selected (see
standard display), switch to WSG ON (ON flashes).
Press the ENTER key. Setting is complete.
www.dimplex.eu
P10 – Operation with external room temperature
controller
NOTE
The device has an integrated room temperature con-
troller with week program. But if the device is to be
controlled via an external controller, program P10
must be set to ON.
Call up the installer menu.
Confirm the PIN code four times with the ENTER
key. Display P9 flashes.
Use the keys to select P10. Display flashes.
Press the ENTER key. OFF flashes.
Use the keys to select ON. ON flashes.
Press the ENTER key. Setting is complete.