Serial Startup Code Master Enable [Y/N]=N?
Should the debugger fail to come up to a prompt, the last code
displayed will indicate how far the initialization sequence had
progressed before stalling.
Serial Startup Code LF Enable [Y/N]=N?
A line feed can be inserted after each code is displayed to prevent it
from being overwritten by the next code. This is also enabled by an
ENV parameter:
The list of LED/serial codes is included in the section on MPU,
Hardware, and Firmware Initialization found in Chapter 1 of the
PPCBug Firmware Package User's Manual listed in
Related

Configuring the VMEbus Interface

ENV asks the following series of questions to set up the VMEbus interface
for the MVME5100. To perform this configuration, you should have a
working knowledge of the Universe ASIC as described in your
MVME5100 Programmer's Reference Guide.
VME3PCI Master Master Enable [Y/N] = Y?
PCI Slave Image 0 Control = 00000000?
The configured value is written into the LSI0_CTL register of the
Universe chip.
PCI Slave Image 0 Base Address Register = 00000000?
The configured value is written into the LSI0_BS register of the
Universe chip.
PCI Slave Image 0 Bound Address Register = 00000000?
The configured value is written into the LSI0_BD register of the
Universe chip.
PCI Slave Image 0 Translation Offset = 00000000?
The configured value is written into the LSI0_TO register of the Universe
chip.
http://www.motorola.com/computer/literature
Documentation.
Set up and enable the VMEbus Interface. (Default)
Y
N
Do not set up or enable the VMEbus Interface.