34933A D-Sub Connectors For One-Wire Mode - Agilent Technologies Switch/Measure User Manual

Multifunction switch/measure unit
Table of Contents

Advertisement

5
Matrix Switch Modules

34933A D-Sub Connectors for One-Wire Mode

Matrices 1 and 2
1C4
2C4
1
NC
18
NC
1C3
34
NOTE: Conventions for these
drawings and tables as they
relate to pinout information:
2R4 means Matrix 2, Row
4.
1C5 means Matrix 1,
Column 5
4C2 bypass means: Matrix
4, Column 2, and the
connection bypasses the
100 in-rush resistor that
protects the reed relays
Matrices 3 and 4
3C4
4C4
1
NC
18
3C3
NC
34
WARNING
WARNING::
As a safety
feature, interlock pins (17
and 33) must be shorted to
enable the Analog Bus
relays, which are on Matrix
2, to close. The optional
34933T-002 (for 1-wire)
terminal block shorts these
pins for you. This safety
feature protects inadvertent
routing of high voltages
from the Analog Buses to
the D-sub connector of the
module.
160
1C4
2C4
1R4
2R4
1C5
bypass
bypass
2
3
4
5
6
7
1C3
2C3
1C1
2C1
1C2
bypass
bypass
bypass
bypass
19
20
21
22
23
2C3
1C1
2C1
1R3
2R3
38
35
36
37
39
40
Description Pin Description Pin Description
1R1
49
1C2
1R2
27
2C2
1R3
39
1C3
1R4
5
2C3
2R1
50
1C4
2R2
28
2C4
2R3
40
1C5
2R4
6
2C5
1C1
37
1C6
2C1
38
2C6
3C4
4C4
3C5
3R4
4R4
bypass
bypass
2
3
4
5
6
7
3C3
4C3
3C1
4C1
3C2
bypass
bypass
bypass
bypass
19
20
21
22
23
4C3
3C1
4C1
3R3
4R3
38
35
36
37
39
40
Description Pin Description Pin Description
3R1
49
3C2
3R2
27
4C2
3R3
39
3C3
3R4
5
4C3
4R1
50
3C4
4R2
28
4C4
4R3
40
3C5
4R4
6
4C5
3C1
37
3C6
4C1
38
4C6
1C5
2C5
2C5
NC
NC
bypass
bypass
8
9
10
11
12
1C6
2C6
2C2
1R2
2R2
1C8
bypass
bypass
24
25
26
27
28
29
1C2
2C2
1C6
2C6
NC
bypass
bypass
41
43
44
45
42
Pin Description
23
1C7
13
24
2C7
14
35
1C8
29
36
2C8
30
1
1C1 bypass
21
2
2C1 bypass
22
7
1C2 bypass
43
8
2C2 bypass
44
41
1C3 bypass
19
42
2C3 bypass
20
3C5
4C5
4C5
NC
NC
bypass
bypass
8
9
10
11
12
3C6
4C6
4C2
3R2
4R2
3C8
bypass
bypass
24
25
26
27
28
3C2
4C2
3C6
4C6
NC
bypass
bypass
41
43
44
45
42
Pin Description
23
3C7
13
24
4C7
14
35
3C8
29
36
4C8
30
1
3C1 bypass
21
2
4C1 bypass
22
7
3C2 bypass
43
8
4C2 bypass
44
41
3C3 bypass
19
42
4C3 bypass
20
Matrices 1 & 2
Matrices 3 & 4
For orientation, the D-sub connector
end of the module is facing you.
1C7
2C7
1C7
2C7
NC
bypass
bypass
13
14
15
16
17
2C8
NC
NC
GND
30
31
32
33
1C8
2C8
1R1
2R1
NC
bypass
bypass
47
48
49
46
50
Pin Description
1C4 bypass
3
GND
2C4 bypass
4
No connect pins:
11-12, 17-18,
1C5 bypass
9
31-32, 34, and
2C5 bypass
10
45-46
1C6 bypass
25
2C6 bypass
26
1C7 bypass
15
2C7 bypass
16
1C8 bypass
47
2C8 bypass
48
3C7
4C7
3C7
4C7
Interlock
bypass
bypass
13
14
15
16
17
4C8
NC
NC
Interlock
29
30
31
32
33
3C8
4C8
3R1
4R1
NC
bypass
bypass
47
48
49
46
50
Pin Description
3C4 bypass
3
Interlock
4C4 bypass
4
Interlock
3C5 bypass
9
No connect pins:
11-12, 18, 31-32, 34,
4C5 bypass
10
and 45-46
3C6 bypass
25
4C6 bypass
26
3C7 bypass
15
4C7 bypass
16
3C8 bypass
47
4C8 bypass
48
34980A User's Guide
Pin
33
Pin
17
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agilent 34980a

Table of Contents