• The fan prover switch makes allowing 24 VAC to the normally open R2 contacts.
• The normally open R2 contacts close and 24 VAC is sent to the main coil of the gas
valve.
• The main burner is ignited and the water heated to steam.
• Steam enters the cabinet and the compartment thermostat closes at 193 degrees.
• The "Sure Cook" light is de-energized.
• If in the timed mode, 115 VAC is sent to the timer motor and the timer begins
counting down.
• The condensate solenoid is energized sending cold water down condensate spray
nozzle pulling the steam around the product and down the drain.
6. When the timer times out or the unit is switched to the timed mode (with no time on the
timer) from the manual mode, 115 VAC is sent to the 3 second timer and then to the buzzer
for 3 seconds.
7. Whenever the water level drops below the high probe for 5 seconds 115 VAC is sent to the
FILL terminal again.
8. When the on/off lever is turned off :
• The drain is mechanically opened, and the generator begins to drain.
• The red "Power On" indicator light is de-energized.
• 115 VAC is sent to the 3-minute timer and the fill solenoid is energized for 3 minutes
flushing the drain.