Cleveland 24-CEM-24 Specifications

Cleveland 24-CEM-24 Specifications

Two compartment, pressureless electric steam generator 24, 36 or 48 kw, 24” wide cabinet base design classic series

Advertisement

Quick Links

Cleveland
CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
Cleveland Classic Series
TWO COMPARTMENT, PRESSURELESS
ELECTRIC STEAM GENERATOR
24, 36 OR 48 KW, 24" WIDE CABINET BASE DESIGN
Cleveland Standard Features
I
Cooking Capacity for up to six 12˝ x 20˝ x 2
I
Pressureless cooking with forced convection steam, permitting
doors to be opened while cooking continues.
I
Solid State Controls operate water level and safety functions.
I
Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.
I
Instant Steam Standby Mode: Holds generator at steaming
temperature. Allows unit to start cooking instantly.
I
Durable 14 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
I
Separate Main Power Switch for "On/Off"
I
Exclusive Steam Cooking Distribution System: The exclu-
sive Convection Jets produce a high velocity convection steam
without fans. Coved Corner design in cooking compartment dis-
tributes heat evenly and is easy to keep clean. Creased top & bot-
tom enhance drainage. Cold Water Condenser for each
compartment maintains a dry steam. Fully insulated cooking com-
partment for thermal efficiency. Removable Stainless Steel Slide
Racks for easy cleaning.
I
Exclusive "Cool to the Touch" Compartment Door Design:
Free floating inner door with reversible door gasket provides
an air tight seal. Stainless Steel Slam/Latch Door Latch
mechanism provides greater reliability.
I
Left Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
I
Modular Cabinet Base with Hinged Door.
I
Electric Steam Generator: Automatic Water Fill on start up.
I
Automatic Generator Drain at shutdown: Contains a "Water
Jet" Spray Rinse Cleaning Cycle to keep drain clear.
I
Automatic Water Level Control System with Low Water
Power Cut-off Circuit.
I
Steam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam Generator Pressure
Gauge.
I
Secondary Low Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI. MN.
MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo, NY,
Wash. DC)
I
NSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
I
Standard voltage 208 or 240 volts, 60 Hz, 3 phase.
I
All Controls are serviceable from the front.
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
CONVECTION
STEAMERS
1
˝ deep Cafeteria Pans.
2
Tel: 1-216-481-4900
Web Site: www.ClevelandRange.com
Fax: 1-216-481-3782
Email: Steam@ClevelandRange.com
MODELS:
24-CEM-24
24-CEM-36
Short Form Specifications
Shall be Two Compartments, CLEVELAND Convection Steamer, Model 24-
CEM- _____ , Electric Steam Generator, _____ KW, _____ volts, _____ phase, 3
wire. Solid State Controls operate timing, water level and safety functions.
Electric Steam Generator with Automatic Water Fill on start-up and Automatic
Blowdown with additional Manual Drain Valve, For each cooking compart-
ment: 60 minute Mechanical Timer, Manual Operation Mode and Cold Water
Condenser. Type 304 Stainless Steel cooking compartment.
Options & Accessories
Ë Right Hand Door Hinging, Controls on the Left (DHR)
Ë Electronic Timer with Compensating Load Feature (ETC)
Ë ON/OFF Steam Switch only for compartment controls (MC)
Ë Cafeteria pans in depths of 1˝, 2
Ë Voltages other than standard
Ë Power Take Off Kit (EPTO), Kettle Interconnecting Kit (IMK)
Ë Correctional Packages
Ë Stainless Steel Base Frame (FSS)
Ë Compartment Door Steam Shut Off Switch (SCS)
Ë Boiler Descaling Pump Kit (107142)
Ë Water Filters
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
24-CEM-48
˝, 4˝ and 6˝
1
2
III
SECT.
PAGE
0707
1

Advertisement

loading

Summary of Contents for Cleveland 24-CEM-24

  • Page 1 Ë Boiler Descaling Pump Kit (107142) Ë Water Filters Web Site: www.ClevelandRange.com Email: Steam@ClevelandRange.com Project ________________________________ Item __________________________________ Quantity _______________________________ FCSI Section ____________________________ Approval _______________________________ Date __________________________________ 24-CEM-24 24-CEM-48 24-CEM-36 Short Form Specifications ⁄ ˝, 4˝ and 6˝ SECT. PAGE 0707...
  • Page 2 Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL, NSF and CSA.

This manual is also suitable for:

24-cem-3624-cem-48