Technical specifications
9.5 Electrode selection
Empty pipe detection
The installation has to fulfill the following limitations for usage of the empty pipe detection
function:
• media conductivity ≥ 20 μS/cm
• length of cable at remote installation ≤ 50 (150 ft)
• special shield cable must be used
Note for MAG 1100 sizes DN 2 and DN 3:
• empty pipe detection is not available
• media conductivity ≥ 30 μS/cm
Note for MAG 5000/6000 CT (FW 3.03):
• empty pipe detection is not available
9.4
Liner selection
Table 9-13
Liner
EPDM
Ebonite
PTFE
PFA
Linatex
Soft rubber
9.5
Electrode selection
Table 9-14
Electrodes
Stainless Steel
Hastelloy C22
Hastelloy C267
82
WARNING
Applications
Drinking Water, Wastewater, Chemi‐
cals, Food & Beverage, Pulp & Paper
Drinking Water, Wastewater, Abrasive
Liquids, Chemicals, Food & Beverage,
Pulp & Paper
Drinking Water, Wastewater, Abrasive
Liquids, Chemicals, Food & Beverage,
Pulp & Paper
Applications
Drinking Water, Low abrasive media, Food & Beverage
Drinking Water, Wastewater, Fine low abrasive media
Drinking Water, Wastewater, Chemicals, Food & Beverage, Pulp
& Paper
Drinking Water, Wastewater, Chemicals, Food & Beverage, Pulp
& Paper
Abrasive media
Drinking Water, Wastewater, Abrasive media, Chemicals
Chemical Resistance
Reducing acids, Oxidicing acids, Or‐
ganic acids, Alkalis, Diluted salts
Reducing acids, Oxidicing acids, Or‐
ganic acids, Alkalis, Diluted salts
Reducing acids, Oxidicing acids, Or‐
ganic acids, Alkalis, Diluted salts
Operating Instructions, 12/2021, A5E03005599-AE
SITRANS FM MAG 3100