Remote Installation - Siemens SITRANS FM MAG 3100 Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for SITRANS FM MAG 3100:
Table of Contents

Advertisement

See also
Cable data (Page 79)
5.2

Remote installation

Note
Remote installation only
The following applies to remote installation of MAG 5000 / 6000 or MAG 6000 I.
1. Unscrew and remove terminal box lid.
2. Mount the two terminal blocks as shown and insert electrode cable plug
and 83) and coil cable plug
Terminals electrode cable: 82, 0 and 83
Terminals special electrode cable: 84, 83, 0, 82 and 81
Terminals coil cable: 85; 86
Note
Special electrode cable
Special electrode cable must be connected to terminals 84, 83, 0, 82 and 81.
Figure 5-1
SITRANS FM MAG 3100
Operating Instructions, 12/2021, A5E03005599-AE
(terminals 85 and 86).
Terminal box without blocks
Connecting
5.2 Remote installation
(terminals 82, 0
45