4.3.2

Torque values

Torque calculations
Overtightened bolts
Leakage/damage to flowmeter or piping may arise if bolts are overtightened.
All values are theoretical and are calculated on the assumption that:
• All bolts are new and material selection is according to EN 1515-1 table 2.
• Gasket material not exceeding 75 shore A is used between the flowmeter and mating flanges.
• All bolts are galvanized and adequately lubricated.
• Flanges are made of carbon steel.
• Flowmeter and mating flanges are correctly aligned.
Torque values
Note
Conversion to F/Lbs
To convert the torque values from Nm to F/Lbs multiply by 0.74.
Table 4-1
Minimum and maximum torques for EN 1092-1 PN 6 to PN 16 in Nm
Nominal
size
Liner
PFA, PTFE,
Ebonite
mm
inch Min
Max
15
½
-
-
25
1
-
-
32
-
-
40
-
-
50
2
-
-
65
3.9
4
80
3
6.9
7
100
4
10.3
11
125
5
6.4
7
150
6
8.1
9
SITRANS FM MAG 3100
Operating Instructions, 12/2021, A5E03005599-AE
CAUTION
PN 6
Soft rubber,
PFA, PTFE,
EPDM, Linatex
Ebonite
Min
Max
Min
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
3.2
4
-
5.7
6
-
8.7
9
-
5.5
6
-
7.2
8
-
EN 1092-1
PN 10
Soft rubber,
EPDM, Linatex
Max
Min
Max
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Installing/Mounting
4.3 Mounting
PN 16
PFA, PTFE,
Soft rubber,
Ebonite
EPDM, Linatex
Min
Max
Min
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
8.5
9
6.9
10.8
11
8.8
13.8
14
11.6
19.2
20
16.5
29.8
31
26.1
Max
-
-
-
-
-
7
9
12
17
27
33