8.11 Removing the Turbidity/Temperature Sensor

Remove the product from the joinery.
Remove the base panel from the machine, and
disconnect the flood switch assembly.
Remove the wiring harness to the turbidity
sensor.
Remove the 2 screws securing the turbidity
sensor to the sump.
Pull the sensor out to release from the sump.
Reassemble in reverse order.

8.12 Removing the Diverter Valve

FC4 &6 models only
Remove the product from the joinery.
Remove the base panel from the machine, and
disconnect the flood switch assembly to remove
the base panel completely.
Remove the wiring harness to the diverter valve.
Remove the clamp securing the diverter valve to
the sump.
Pull the valve off the sump spigot.
When reassembling ensure the o-ring is fitted
correctly to ensure sealing.
Use a standard hose clamp to secure diverter
valve to the sump, reconnect the wiring.

8.13 Removing the Flow Meter

Remove the product from the joinery.
Remove the side panel, refer section 8.3
Remove the harness to the flow meter.
Remove the hoses to the flow meter.
Remove the vent cap from the inside of the
wash tub. The assembly will now remove from
the chassis.
8 SERVICING THE COMPONENTS
D
33