Totalizing (Not Available In 4/5 Key Models); Counting Function ( Not Available In 4/5 Key Models ); Sampling - Excell X Series User Manual

Weighing scale
Hide thumbs Also See for X Series:
Table of Contents

Advertisement

EXCELL PRECISION CO., LTD.
value". Then press
Press
2-2-6 Totalizing
1. Weight Totalizing
Place goods on the platter, after stable and press
Then the display shows the total number of additions and the totalized weight value.
And the (M+) indication "  " will flash on the display. The indicator will recover to show
the weight value of the goods on the platter after 3 seconds and the (M+) indication "  "
is on.
The indicator allows the next totalizing operation, even when the weight value does not
return back to zero. The
than 10d. The indicator will save the totalized weight value after the weight is stable.
The indicator can totalize positive or negative weight but can't do both at the same time.
The totalized weight store must be reset to zero before it is possible to select positive or
negative totalizing mode.
The totalizing function can be used up to a maximum of 9999 times before it must be
reset. The totalizing display is limited to 6 digits maximum.
When totalizing, RS-232 will also output. ( Refer to F5 setting)
2. Clear Totalized Weight Values
 Press
 When changing between weighing and counting mode, or selecting weighing unit, the
indicator will automatically clear all the totalized weight values.
 The indicators will automatically clear all the totalized weight values after turning on.
3. Recall Totalized Weight Values
Press
key to display the total number of additions and the totalized weight value.
And the (M+) indication "  " will flash on the display. The indicator will return to the
weighing mode after 3 seconds.
The indicator will not display the negative sign "-" for negative totalized weight values
when recalling a totalized weight value, but when printing, the negative sign "-" will be
printed out (transmitted serially) for each negative weight and negative totalized weight.
2-3 Counting Function

2-3-1 Sampling

Press
Select sample quantity and then place samples on the platter, and then press
the display shows "
After stable, the scale enters into counting mode and the display shows sample quantity.
 Sample Too Small (
 Unit Weight Too Small (
When sampling, the above two symbols indications are on. Under such conditions, the
scale can still work, but may result in lower count precision.
When using 2-segment weighing mode, the above two symbol indications change to
Range 2 and Range 1 and the two symbol indications are off.
02036XXX
key again  Clear "High limit value" and "Beeper value"
key then press
(not available in 4/5 key models)
key is functional, when the weight value changes by more
(not available in 4/5 key models)
then
key to clear all totalized weight values.
(not available in 4/5 key models)
(not available in 4/5 key models)
key to select sample quantity from 10, 20, 50,100
.
. .
)
. . .
. . . .
)
Pcs
key 6 times continuously  Clear all values.
".
 Sample is less than 20 divisions.
 Unit weight is less than 0.2 division.
(0.1 d for Brazil regulation)
10
key to save the weight value.
ZSME300000422