Device Information - Dimplex LIA 0608HWCF M Installation And Operating Instruction

Split air-to-water heat pump with hydrotower compact unit
Table of Contents

Advertisement

LIA 0608HWCF M - LIA 0911HWCF M

13 Device information

1
Type and order code
2
Design
Heat source
2.1
Version
2.2
Controller
2.3
Thermal energy metering
2.4
Installation location
2.5
Performance level
3
Operating limits
3.1
Heating water flow/return
3.2
Cooling water flow
3.3
Air (heating)
3.4
Air (cooling)
4
Flow/sound
4.1
Heating water flow / internal pressure differential
Nominal flow according to EN 14511
Minimum heating water flow rate
4.2
Sound power level outside
Normal operation A7/W55 EN12102
4.3
Sound power level lowered operation
4.4
Sound power level inside
5
Dimensions, weight and filling quantities
1
5.1
Device dimensions
indoor unit
5.2
Weight outdoor unit / incl. packing
5.3
Device connections for heating
5.4
Device connections for domestic hot water
5.5
Refrigerant/total filling weight
5.6
GWP value / CO
equivalent
2
5.7
Lubricant
Type
5.8
Maximum operating pressure
5.9
Domestic hot water cylinder
5.10 Electrical pipe heater
5.11 Start-to-leak pressure, safety valve
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
Outdoor unit
Indoor unit
RCD type
6.2
Control voltage / fuse protection
6.3
Degree of protection according to EN 60 529 Inside 7
6.4
Starting current limiter
6.5
Rotary field monitoring
6.6
Starting current
6.7
Nominal power consumption at A7/ W35 (EN14511)
6.8
Nominal current at A7/W35
6.9
Nominal power consumption at A2/ W35 (EN14511)
6.10 Power consumption of compressor protection (per compressor)
6.11 Power consumption of fan
7
Complies with the European safety regulations
www.glendimplex.de
H x W x D mm
Outdoor unit
H x W x D mm
--- / t
Volume
Heat exchanger area
Permissible operating temperature °C
Permissible operating pressure
with 230 V connection
with 400 V connection
452172.66.01-EN · FD 0204
LIA 0608HWCF M
Air
Split
WPM Touch
--
Indoors/outdoors
Variable
° C
up to 65 / from 12
° C
7 to 25
° C
-25 to +35
° C
-5 to +43
m³/h
0.75
-
-
58
dB(A)
dB(A)
53
dB(A)
42
1880 x 595 x 600
712 x 1008 x 426
kg
60 / 65.5
Inches
3/4
Inches
3/4
Type/kg
R32 / 1.5
675 / 1.01
Synthetic oil
bar
3
litres
193
2.0
75
bar
10
6
bar
3
1~/N/PE 230 V (50 Hz) / C20A
1~/N/PE 230 V (50 Hz) / B32A
3~/N/PE 230 V (50 Hz) / B16A
B
1~/N/PE 230 V (50 Hz) / B13A
IP X4
Inverter
Yes
A
5
kW
1.24
A
5.4
kW
1.26
W
--
W
100
See CE declaration of conformity
English
LIA 0911HWCF M
Air
Split
WPM Touch
--
Indoors/outdoors
Variable
up to 65 / from 12
7 to 25
-25 to +35
-5 to +43
1.47
-
60
55
42
1880 x 595 x 600
865 x 1118 x 523
78.5 / 92
3/4
3/4
R32 / 1.65
675 / 1.2
Synthetic oil
3
193
2.0
75
10
6
3
1~/N/PE 230 V (50 Hz) / C20A
1~/N/PE 230 V (50 Hz) / B32A
3~/N/PE 230 V (50 Hz) / B16A
B
1~/N/PE 230 V (50 Hz) / B13A
IP X4
Inverter
Yes
5
2.00
8.7
2.02
--
100
See CE declaration of conformity