Advertisement

Quick Links

Manual for Training Case
KNX & KNX Programming
with ETS
2022-05-16_309711 01

Advertisement

Table of Contents
loading

Summary of Contents for Theben Training Case KNX

  • Page 1 Manual for Training Case KNX & KNX Programming with ETS 2022-05-16_309711 01...
  • Page 2: Table Of Contents

    KNX devices used in the case System devices Terminal devices Start-up KNX IP connection XLR connection Actual start-up Resetting devices to factory settings BUS reset Resetting devices Extending the case with further devices Support Contact Manual for the training case KNX...
  • Page 3: Further Information On Theben Knx Is Available At

    Further information on Theben KNX is available at: 1 Further information on Theben KNX is available at: Further information on Theben KNX is available at: https://www.theben.de/ The functions of the operating controls of individual devices are described in the operating instructions provided at https://www.theben.de/...
  • Page 4: Case Views

    Case views 2 Case views Manual for the training case KNX...
  • Page 5: Case Lid Showing Rooms / Functions

    Case views 2.1 Case lid showing rooms / functions 2.2 Case base with view of devices Manual for the training case KNX...
  • Page 6: Safety Information And Instructions On Preparing The Case Safely

    The earthed plug or the IEC plug of the mains cable must always remain accessible, so the mains cable can be disconnected in an emergency.  The device is suitable for use in schools for supervised pupils aged 11 years or older. Manual for the training case KNX...
  • Page 7: Key To Symbols

    Theben AG herewith declares that this type of radio installation complies with Directive 2014/53/EU. The complete text of the EU Declaration of Conformity is available at the following Internet address: www.theben.de/red-konformitaet...
  • Page 8: Proper Use

    − may only be used at altitudes up to 2000 m. − may only be used in environments with a relative humidity up to 80 % RH (non-condensing). 3.5 Cleaning device Only clean the training case with a damp cloth when it is open. Manual for the training case KNX...
  • Page 9: The Knx Bus System

    (data packets). Devices receiving telegrams and converting the commands they contain into actions are called actuators. Sensors represent the command transmitters, actuators the command receivers. Manual for the training case KNX...
  • Page 10: Knx Devices

    The transformer module determines the medium for which the bus coupling unit is used. Common variants are bus coupling units with transformer module for KNX TP (twisted pair) and for KNX PL (power line). Manual for the training case KNX...
  • Page 11: What Can Knx Be Used For

    Internet (online catalogue) or from the database provided by the manufacturer (e.g. via their website).  Setting the parameters of the application programmes.  Connecting the appropriate communication objects of the individual application programmes by means of group addresses. Manual for the training case KNX...
  • Page 12 KNX products provide these data free of charge. They are available either directly from the manufacturer or on the internet. Alternatively, the ETS online catalogue can be used. After importing these data into the ETS, the actual configuration can begin. Manual for the training case KNX...
  • Page 13: Knx Secure

    The ETS sends the runtime keys to the device to be configured via the bus. Transmission takes place by encrypting and authenticating them via the tool key. The runtime keys are never sent in plain text via the bus. Manual for the training case KNX...
  • Page 14 To start up the device without KNX Data Secure, select the device in the 'Topology' or 'Devices' section and set the 'Secure start up' option in the 'Properties' area of the 'Settings' tab to 'Disabled'. Manual for the training case KNX...
  • Page 15: Knx Devices Used In The Case

     This voltage supplies the bus coupling units via which each KNX device communicates with the other networked KNX devices 5.1.2 KNX USB interface https://www.theben.de/de/schnittstelle-usb-knx-9070397  For communication between PC and KNX system to be programmed  Support of KNX Data Secure communication Manual for the training case KNX...
  • Page 16: Terminal Devices

     Manual operation on the device (even without bus voltage)  Links, type of contact (opening contact/NO contact) and participation in central commands such as permanent on, permanent off, central switching and save/load scene Manual for the training case KNX...
  • Page 17  Manual operation on the device (even without bus voltage)  All inputs can be operated with different voltages and at different potentials  Free allocation of functions: switch/push button, dimming, blinds/roller blinds, counter, repeat telegram, sequences Manual for the training case KNX...
  • Page 18  Also suitable for controlling fans  Up to 2 MIX or MIX2 extension modules can be connected to a base module  Device and KNX bus module can be exchanged independently of each other Manual for the training case KNX...
  • Page 19  Manual start-up and operation of the actuators are also possible without KNX bus module  LED switching status indicator for each channel  Manual operation on the device (even without bus voltage) Manual for the training case KNX...
  • Page 20  Free allocation of functions: switch/push button, dimming, blinds, valuator, sequences, temperature measurement, LED control  2 NTC inputs for actual temperature measurement from -5 °C to +100 °C  They can be installed with conventional push buttons/switches in flush- mounted boxes. Manual for the training case KNX...
  • Page 21 Combinations of two iON KNX are possible with a 2- way mounting plate available as an accessory. The integrated bus coupling unit makes installation and connection to the bus system quick and easy. Manual for the training case KNX...
  • Page 22 During the day, the display shines brighter and thus remains optimally readable. The iON 108 KNX room controller is a multi-touch sensor with 4 buttons (up/down/right/left). Active function (icon) with value/status Previous/next function Operation Manual for the training case KNX...
  • Page 23 The app control of the iON 108 KNX room controller is especially suitable for living rooms, meeting rooms or hotels. When used in a hotel, the pairing is automatically terminated after an adjustable period. Manual for the training case KNX...
  • Page 24  Download the iONplay app from the App Store or Google Play Store. Open iONplay app and press + in the menu bar.  Update Edit: change password, name Delete Search for new devices … Manual for the training case KNX...
  • Page 25 KNX devices used in the case Device list of available iON devices appears.  Select the device and confirm with OK.  Tap on displayed device.  Enter the PIN that appears on the iON display.  Press OK. Manual for the training case KNX...
  • Page 26 Heating  for comfort temperature, temperature reduction at night etc. or use Scenes  to enter new lighting scenarios  If the time set in the ETS application is exceeded, the connection is not established automatically. The devices must be paired again. Manual for the training case KNX...
  • Page 27 - a new physical address is assigned to the device. When dismounting, the device must be pulled - firmly but carefully - out of the upper bracket and tilted slightly forwards. Then it must be removed upwards from the snap-fit. Manual for the training case KNX...
  • Page 28: Start-Up

    This allows crossline KNX communication between different cases (simulating communication between different floors, for example). The KNX IPsecure Router functions as a line coupler. 6.2 XLR connection Further KNX devices can be connected to the XLR socket (BUS input). Manual for the training case KNX...
  • Page 29: Actual Start-Up

    USB cable.  Now the case, or the devices inside, can be configured via the ETS. For programming via the ETS, the KNX USB interface (if necessary, also the KNX IPsecure router) is used. Manual for the training case KNX...
  • Page 30: Resetting Devices To Factory Settings

     This step must be carried out for every device. Afterwards, all parameters and programming settings for the KNX devices will have been deleted and the physical address will once again be 15.15.255. Manual for the training case KNX...
  • Page 31 Resetting devices to factory settings 7.2.1 The programming button of the devices used Push button interface TA 8 S KNX Actuators Weather station (on the bottom) KNX IPsecure Router Manual for the training case KNX...
  • Page 32 Resetting devices to factory settings iON 4/iON 8 The device must be lifted (disengaged) at the top as shown. On the back, the programming button must be pressed. Manual for the training case KNX...
  • Page 33: Extending The Case With Further Devices

    In KNX mode, KNX devices from competitors can of course also be connected and operated. Only devices complying with the safety extra-low voltage guidelines for KNX bus and KNX auxiliary voltage may be connected. Manual for the training case KNX...
  • Page 34: Support

    Support 9 Support If you require technical assistance, our colleagues from the service would be happy to help you. Hotline@theben.de Telephone: +49 7474 692369 Manual for the training case KNX...
  • Page 35: Contact

    Contact 10 Contact Theben AG Hohenbergstr. 32 72401 Haigerloch GERMANY Tel. +49 7474 692-0 Fax +49 7474 692-150 Hotline Tel. +49 7474 692-369 hotline@theben.de Addresses, telephone numbers etc. www.theben.de Manual for the training case KNX...

This manual is also suitable for:

Training case knx programming

Table of Contents