Download Print this page

Installation - Graco 116229 Instructions Manual

Used oil tank monitor

Advertisement

Installation

Installation
Reference only.
Parts are
included in
Kit 240684
F
. 1
IG
Installing the Oil Tank Monitor
NOTE: Although the Oil Tank Monitor is rated for a max-
imum air working pressure of 150 psi and has a recom-
mended operating pressure of 90 psi, Graco
recommends using 50 psi pressure when used with
Graco Diaphragm pumps.
WARNING
PRESSURIZED EQUIPMENT HAZARD
The equipment stays pressurized until pressure is
manually relieved. To reduce the risk of serious injury
from pressurized fluid, accidental spray, or splashing
fluid, follow the pressure relief procedure provided in
your pump instruction manual before servicing.
NOTE: If an air regulator is to be used, be sure that it is
connected to the air inlet port of the oil level monitor.
See Fig 1 Graco Used Oil Evacuation Installation Guide.
1. Shut down system and relieve system pressure. Fol-
low the Pressure Relief Procedure found in the
2
Reference only.
Part no. 236265
Pump Module Manual that initially came with your
system.
2. Remove thread protector and discard.
3. Connect float chain (A).
F
. 2
IG
4. Connect air supply to inlet port (B, F
Reference only.
Parts are included
in Kit 240684
1/4 NPT x 1/8 NPT
Nipple
User Supplied
. 3).
IG
309238E

Advertisement

loading