Hitachi GS4000 Series Quick Start Manual page 41

Hide thumbs Also See for GS4000 Series:
Table of Contents

Advertisement

Procedure 1.
Attach a power cable
Attach power cables to all the power supply units in GS4000-320E (AC).
When connecting the device to a power supply unit, use only grounded
Warning
power outlets. Failing to use grounded outlets creates a shock hazard.
Use the power cable provided with a chassis. If you use a power cable other
Warning
than this, it could cause a fire or an electric shock.
Before attaching a power cable, make sure that all the switches of GS4000 are
NOTE
turned OFF.
Procedure 2.
Install a memory card.
Insert a memory card into both the memory card slot 0 and the memory card slot 1 of a basic control unit (BCU0). Memory
cards must be installed into both BCU0 and BCU1 in case that a basic control unit is redundant.
Caution
While the access indicator of BCU (ACC lamp) is lit, the memory card is being accessed. DO NOT
pull out a memory card or turn off the power switch while the memory card is being accessed. If
so, you could permanently damage the memory card.
NOTE
When inserting a memory card, the surface labeled with the part number "HN-F9244-66X" should
be faced up.
NOTE
Use a standard type of memory card provided by HITACHI. The operation cannot be guaranteed if
a memory card other than that is used.
When installing a memory card using an option license for GS4000, make sure that the
manufacturing number of a device put on the label of a memory card matches the serial number
of an option license. (You can check these numbers using a packing list provided with GS4000.)
Procedure 3.
Connect a setup terminal to GS4000-320E (AC).
1.
Connect a setup terminal to the CONSOLE port of BCU (BCU0) using a RS-232C cross cable.
2.
Start up a setup terminal.
3.
Start up communication software
NOTE
GS4000-320E (AC) is pre-configured in a way that a setup terminal can be connected to a
CONSOLE port of BCU0 when it is shipped from the factory. Connect a setup terminal to a
CONSOLE port of BCU0 in case that a basic control unit is redundant.
NOTE
As for the setup of communication software, see the communication software manual.