Table 15. Rtlu Alarms - ADC PG-FlexPlus FLL-814 Manual

24 channel integrated central office line unit
Table of Contents

Advertisement

SCP-FLL814-012-04H
Alarms
HDSL PAYLOAD SYNC
* HDSL INPUT VOLTAGE
TALK BATT FAILURE
ONHOOK BATT FAILURE
RTLU RINGER FAILURE
LOW TEMPERATURE
HIGH TEMPERATURE
COLU-RTLU MISMATCH
RTCU HW SUPPORTED
EEPROM FAILURE
RTLU HW FAULT
RT EXTERNAL ALARM 1
RT EXTERNAL ALARM 2
RT EXTERNAL ALARM 3
RT EXTERNAL ALARM 4
RT FAN FAILURE
* HDSL INPUT VOLTAGE option is displayed, set and cleared only on a line-powered system.
74

Table 15. RTLU Alarms

Value
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
CR, MJ, MN, NA, NR
Description
HDSL payload is out of sync
HDSL input voltage is less than 170
Vdc
Talk battery failure at RTLU
On-hook battery failure at RTLU
RT ringer failure at RTLU
Temperature at RTLU is too low
Temperature at RTLU is too high
COLU-RTLU mismatch
RTCU hardware installed is not
supported
COLU memory checksum is incorrect
Fault detected in RTLU hardware
RT External 1 Alarm reported
RT External 2 Alarm reported
RT External 3 Alarm reported
RT External 4 Alarm reported
RT Fan Failure reported
April 22, 2003
Default
MJ
MN
MJ
MJ
MJ
MN
MJ
MJ
MN
MN
MN
MN
MN
MN
MN
MN