Power Saving Delay
Sets the amount of time before initiating the standby state specified in Power Saving
Mode when no signal is present
Options: 1 Minute, 5 Minutes, 15 Minutes, 30 Minutes, 60 Minutes; Default: 5 Minutes
Power On Delay (URP75 / URP85 only)
Sets the amount of time to delay between an ON command being received and the display
leaving standby. This can be useful when multiple displays are on the same electrical
circuit, and it is beneficial to avoid all displays leaving standby simultaneously, causing a
large inrush of current.
Options: 0-10 seconds, in 0.1 second increments; Default: 0 seconds
Power Down Mode
Set the action to take when the display enters standby
Options: Standby Mode, Networked Standby Mode, Fast Start; Default: Standby Mode
Standby Mode: The lowest power standby setting. CEC, LAN, DB9 RS232, and USB
communication are disabled. IR, Keypad connector will remain active.
Note: To remove display from standby with the IR remote or keypad, IR Remote Lock
or Keypad Lock must be disabled.
Note (URP75 / UPR85): The Turn On action in the Schedule feature will not work if the
Power Down Mode setting is set to Standby Mode. To allow the Turn On action to
occur, set Power Down Mode to Networked Standby Mode or Fast Start.
Networked Standby Mode: The display will enter a low power standby state with LAN,
DB9 RS232, USB and IR communications active.
Fast Start: The display will enter a standby state with partially reduced power, allowing for
3-5 second wait between an ON command being sent, and image being displayed. IR,
Keypad, CEC, LAN, DB9 RS232, and USB communication will remain active.