How the Rinnai Novo models start
By pressing the power button 'On' the fire will start the ignition sequence.
Ignition sequence
1. When the On/Off button is pressed on the control panel, the infra-red receiver window will pulse
green.
2. The ignition sparker will operate, and as soon as a spark is sensed gas will flow to the main
burner.
3. When the main burner establishes a flame, the fire will automatically modulate between the
burner settings to achieve and maintain the default set temperature of 22 °C
Do not unplug or turn off the mains power supply to the fire as this will stop the convection fan
from cooling down the unit. The convection fan operates for several minutes after the fire has been
turned off.
Power cut
If power is disrupted while the Novo is operating, once the power has been restored, the fire will
go into power failure mode, the LED indicator will flash red, there will flashing zeros in the error
display window
, and if you've had the Wi-Fi module installed (purchased separately) the app 00
2
(mains power failure) will appear on your smart device.
To reset the fire, press the ON/OFF button on the control panel, remote control, or on the app twice
to turn the fire back on.
Position of your Novo Inbuilt on a wall
If installing the Novo Inbuilt up the wall in an elevated position, air from the convection fan,
depending on the room configuration, could create draughts. This needs to be factored when
determining the location of the fire.
Wall surface above the fire
The temperature of the wall surface directly above the appliance may get warm and discolour
paint finishes or distort wall coverings. For durability of surfaces, please contact the manufacturer
for their specification. The finish needs to be able to withstand temperatures of up to 65 °C above
ambient.
On initial start-up (no additional buttons pressed), the Novo modulates the flame and heat output to try and maintain the
1
default setting of 22 °C. If the room temperature starts to climb above 22 °C the unit will modulate to its lowest flame and
fan setting, but will not turn off. Depending on the room size this could mean the room temperature could steadily rise.
Error display window, the error will show through the two narrow cutouts—you will need to walk up to the fire to look