INSTALLATION
BUILT–IN CONSTRUCTION DETAILS
5,5 cm=
(2-3/16")
Standard layout for non-combustible enclosure:
NOTE: See Fig. 05
127cm
(5")
for ventilation notes.
Layout for insulated jacket only - combustible enclosure:
NOTE: See Fig. 05
for ventilation notes.
Note:
The gas connection must be visible to the user (through a door opening or similar).
Gas piping and connectors must be clamped within the the enclosure to avoid contact with moving parts and hot surfaces.
Where the gas piping passes through an opening in the enclosure, the piping must be protected for a distance of at least 2" (50mm) either side
of the opening.
The gas connector must comply with the Standard for Connectors for Outdoor Gas Appliances & Manufactures Homes, ANSI Z21.75/ CSA 6.27.
The connection must be no longer than 6' (1820mm) in length and be suitable for outdoor installation.
34,93 cm
(13 3/4")
Bottom of
support flange
56,7 cm (22-3/16")
64,77 cm (25 1/2")
50,8 cm
(20")
28,26 cm
(11 1/8")
50,8 cm
(20")
grill
exhaust
7,6 cm (3") (to non-combustible
construction / minimum lid
clearance)
45,7 cm (18") (to combustible
construction)
25,4 cm (10")
(BH1-30R illustrated)
2,5 cm (1")
NOTE: BGB models, if using a backguard
apron or rear wall, locate electrical service
on the right hand side for rotisserie motor
9,5cm (3 3/4" min.) (For Lid Clearance)
57,79 cm (22 3/4")
10x10 cm (4 x 4")
opening for gas
supply line
90.17 cm
(35 1/2" max)
opening for access
doors/drawers
(see Fig. 05 and 06 for
ordering information)
47,6cm (18 3/4") Min. for Lid Clearance
60,33 cm (23 3/4")
10x10 cm (4 x 4")
opening for gas
supply line
90.17 cm
(35 1/2" max)
opening for access
doors/drawers
(see Fig. 05 and 06 for
ordering information)
10
WARNING!
If installing the grill into a
non-combustible enclosure,
all combustible construction
must still be outside the 18
inch / 45,7cm clearance
zone. If your island is made
of stucco over the top of
wooden studs, the wood can
not be inside the 18 inch
clearance zone to
combustible, even though
the stucco is what is
touching the grill area.
INSULATED JACKET
Size
Part No.
30
70859
FIG.04