Electrical connection
WARNING!
Electrical wiring must be done by qualified person(s) in accordance with all applicable
●
●
codes and standards and the unit must be grounded.
Turn off electricity at the service panel before wiring the unit.
●
●
A 120 volt, 60Hz AC-only electrical supply is required on a dedicated 20A branch
●
●
circuit. A time-delay fuse or circuit breaker is recommended.
Use only with range hood cord-connection kits that have been investigated and found
●
●
acceptable for use with this model range hood.
Range hood internal blower electrical connection (HCB30/36/48 models only)
Connect the plug present inside the range hood to the internal blower.
1
Remove the junction box cover as shown below.
2
Remove knockouts as required and install a cULus listed 3/4" (19mm) wiring conduit and
3
conduit connector or strain relief in the junction box.
Run three wires for the power supply through the 3/4" (19mm) strain relief or conduit
4
from the power supply to junction box. Tighten the strain relief.
Connect the power supply wires to the range hood wires in the following order using
5
cULus listed wire nuts:
black to black wire
●
●
white to white wire
●
●
green/yellow wire to green wire.
●
●
Close the range hood junction box cover.
6
Complete the installation
Remove all protective wrapping from range hood.
1
Install the filters and grease trays as described in the 'Cleaning and maintenance' section.
2
Turn the power on at the control panel.
3
Check the operation of the range hood as described in the 'Operating instructions' section.
4
22
INSTALLATION INSTRUCTIONS
Power supply conduit
From control panel