Electrical connection
WARNING!
Electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards and the unit must be grounded.
Turn off electricity at the service panel before wiring the unit.
A 120 volt, 60Hz AC-only electrical supply is required on a dedicated 20A branch
circuit. A time-delay fuse or circuit breaker is recommended.
Use only with range hood cord-connection kits that have been investigated and found
acceptable for use with this model range hood.
Range hood internal blower electrical connection (HCB30/36/48 models only)
Connect the plug present inside the range hood to the internal blower.
1
Remove the junction box cover as shown below.
2
Remove knockouts as required and install a cULus listed 3/4" (19mm) wiring conduit and
3
conduit connector or strain relief in the junction box.
Run three wires for the power supply through the 3/4" (19mm) strain relief or conduit
4
from the power supply to junction box. Tighten the strain relief.
Connect the power supply wires to the range hood wires in the following order using
5
cULus listed wire nuts:
black to black wire
white to white wire
green/yellow wire to green wire.
Close the range hood junction box cover.
6
Complete the installation
Remove all protective wrapping from range hood.
1
Install the filters and grease trays as described in the 'Cleaning and maintenance' section.
2
Turn the power on at the control panel.
3
Check the operation of the range hood as described in the 'Operating instructions' section.
4
22
INSTALLATION INSTRUCTIONS
Power supply conduit