Internal blower installation (HCB30/36/48 range hood models only)
The internal blower can be mounted as shown below.
From the inside of the range hood, loosen the 1/2" (12.7mm) screws securing the blower
1
plate to the range hood.
Slide the blower plate towards you and lower it out of the range hood.
2
Attach the blower plate to the blower using the 3/4" (19mm) screws provided.
3
Lift the blower into the range hood, fit the rear of
4
the blower plate onto the mounting bracket.
Lift the front of blower upwards until the screws
5
enter the keyhole slots on the blower plate.
Push the blower away from you (to the rear of the
6
range hood) and tighten the 1/2" (12.7mm) screws
to secure the blower to the range hood.
Blower without plate attached
Inline blower connection (HC36 and HC48 range hood models only)
For inline blower installation see the instructions supplied with the inline blower unit.
INSTALLATION INSTRUCTIONS
Front
Blower with plate attached
Rear
EN
21