Service; Replacing Fan Motors And Blades - Hussmann CW2U-138GE Installation And Operation Manual

Dairy, delicatessen and produce merchandisers impact series
Table of Contents

Advertisement

P/N 428668A

REPLACING FAN MOTORS AND BLADES

See cross section for location of evaporator fans.
Should it ever be necessary to service or replace
the fan motors or blades be certain that the fan
blades are re-installed correctly. T
MUST BE INSTALLED WITH RAISED EMBOSSING
(
PART NUMBER ON PLASTIC BLADES
AS INDICATED ON THE PARTS LIST
case data sheet for each model.)
For access to these fans:
1. Turn off power
2. Remove bottom display pans.
3. Disconnect fan from wiring harness.
4. Remove fan blade.
5. Lift fan plenum and remove screws holding
bottom of motor to fan basket.
6. Replace fan motor and blade.
7. Lower fan plenum.
8. Reconnect fan to wiring harness.
9. Turn on power
10. Verify that motor is working and blade is turn-
ing in the correct direction.
11. Ensure the plenum rests on the case bottom
with no gaps.
12. Replace display pans, Bring merchandiser to
operating temperature before restocking.
Remove
Screws
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)

SERVICE

HE BLADES
)
POSITIONED
. (Refer to the
Hook to Back Panel
WARNING
!
Always
disconnect
power at the main disconnect when
servicing or replacing any electrical
component. This includes, but is not
limited to, such items as fans, heaters,
thermostats and lights.
CW2 Unitized End
For access to these fans:
1. Turn off power
2. Remove bottom display pans.
3. Disconnect fan from wiring harness.
4. Lift off the rear shelf support.
WARNING
!
Do NOT allow product to sit in a
non-refrigerated area.
Medium Temperature
6-1
the
electrical
Left Shelf Support