See the case data sheet set for dimensions. Each
waste outlet will be interconnected with factory
installed drip piping. When unitized cases are
joined, or an end case is to be joined to a lineup of
CW2 models, the waste outlet can be inter-
connected. A drain piping connect kit is required
to change piping from front to back as shown.
P/N 428668A
IPING AND SPLASHGUARDS
Refrig. Outlet
Base
Access Area
Waste Outlet
& Water Seal
Refrig. Outlet
Front
Each merchandiser is supplied with a 2 in. (51mm)
water seal, an adapter, a plug and a street ell. The
street ell and water seal must be installed to
prevent air leakage and insect entrance into the
merchandiser. They should be installed as shown
above.