Language; Over Current Protection; Cfr Set Point - Graco G-Flex 1500 Operation

Hide thumbs Also See for G-Flex 1500:
Table of Contents

Advertisement

Detailed Control Adjustment

Language

The run display and programming menus can be set to
display in English, Spanish (Espanol), French (Fran-
cais), or German (Deutsch).

Over Current Protection

The control has a coarse over-current fault protection
that trips when the output is above the rated current.
The G-Flex 1500 is rated 3A at 120V and 1.5A at 240V.
The operator should monitor the output current to
ensure that it is within the desired range. If an "Over
Current" occurs, press the "1/0" key to restart the con-
trol. The operator should also monitor the temperature
of the coils on the vibratory feeder. The coils should
never be too hot to hold.
14

CFR Set Point

The CFR set point sets the amplitude vibration level that
the control regulates to. The G-Flex 1500 control adjusts
the amplitude automatically to match the CFR set point.
The CFR set point can be adjusted by pressing the UP
and DOWN arrow keys. Hold an arrow key down to
adjust the amplitude setting instead of the CFR set
point.
The CFR set point only appears on the display when the
"Amplitude Source" menu under power settings is set to
"Auto Track" and the CFR sensor is attached. The fea-
ture is included on Version 1.05 software and greater.
332462A

Advertisement

Table of Contents
loading

This manual is also suitable for:

16v133

Table of Contents