Control Menu Layout - Graco G-Flex 1500 Operation

Hide thumbs Also See for G-Flex 1500:
Table of Contents

Advertisement

Control Menu Layout

Normal Operation Display
Press and hold 'Enter' to enter the program menu or get the security menu.
Use the arrow up and down keys to adjust the security number. Press enter to test the security number.
Main Menu
Power Settings
Frequency Settings
Timer Settings
Power Key Interface
Diagnostics
Security
Defaults
Language
Status Line Message
CFR Set Point
Amplitude
Frequency
The normal operating display shows the status of the control with regard to input signals and control settings. They are listed from highest to
lowest in priority. The highest priority message takes precedence over all other messages.
Stop/Run - The Power button has been pushed to disable control operation.
Override - The Power button has been pushed and held so the control will feed without interruption from the "Sensor" or "Run" inputs.
Run Input - The run jumper has not been made.
Zero Speed - The output is off because the output is set to 0.0%.
Run - The feeder is running normally.
Run/CFR - Constant Feed Rate sensor is regulating the feed rate (Autotune
332462A
Sub Menu
Amplitude
Max Amplitude
Min Amplitude
Soft Start Time
Amplitude Source
CFR Positive Gain
CFR Negative Gain
Frequency
Max Frequency
Min Frequency
Frequency Mode
Auto Scan
Resonate Threshold Level [ 200 Default ]
Auto Track Dead Band
On Delay
Off Delay
Empty Bowl Timer
Sensor Polarity
Sensor Type
Run Mode
Empty Bowl
Aux Output Mode
Software Version
Accelerometer
Over Amps
DC Volts
Internal Temperature
Keypad Lock
Security Code
Restore Settings 1
Restore Settings 2
Restore Settings 3
Save Settings 1
Save Settings 2
Save Settings 3
Factory Reset
Pick Language
Normal Display Message Priority
R = 1
Gun/CFR
S = 1
CFR=024.5
A= 40.0%
O = 1
A = 1
F= 60.0 Hz
Adjustments
[ 0.0 to 100.0 ]%
[ 100.0 to 40.0 ]%
[ 0.0 to 95.0 ]%
[ 0.0 to 10.0 ] Seconds (0.0 Default)
[ Auto Tracking Manual, 0-10V, 4-20mA ]
[ 25 Default ]
[ 5 Default ]
[ 5.0 to 140.0 ] Hz (60.0 Hertz Default)
[ 15.0 to 140.0 ] Hz (140.0 Hertz Default)
[ 5.0 to 130.0 ] Hz (45.0 Hertz Default)
[ Auto Tracking, Manual ]
[ Press ENTER to perform an automatic frequency scan ]
[ 64 Default ]
[ 0.0 to 20.0 ] Seconds (0.0 Default)
[ 0.0 to 20.0 ] Seconds (0.0 Default)
[ 5 to 255 ] Seconds (10 Default) **Not used on G-Flex 1500
[ Inverted, Normal ]
[ Auto, NPN, PNP ]
[ Normal, Always On, 2-Speed, High/Low ]
[ Normal, Stop ] **Not used on G-Flex 1500
[ Normal, Inverted, Alarm, Inv Alarm, Air Jet ] **Not used on G-Flex 1500
[ Software Revision Level ]
[ data ]
[ data, data ]
[ data ]
[ data ] °C
[ Unlocked, Amplitude Only, Locked ]
[ 000 to 999 ]
[ 'Enter' Restores User Settings 1 ]
[ 'Enter' Restores User Settings 2 ]
[ 'Enter' Restores User Settings 3 ]
[ 'Enter' Saves User Settings 1 ]
[ 'Enter' Saves User Settings 2]
[ 'Enter' Saves User Settings 3]
[ 'Enter' Resets Control to Factory Default Settings (Shown in bold) ]
[ English, Spanish, French, German ]
Run Input: 1=on/closed & 0=off/open
Sensor input: 1=on/closed & 0=off/open
Output to vibratory feeder: 1=on & 0=off (Not used on G-Flex 1500)
Aux Output: 1=on & 0=off (Not used on G-Flex 1500)
®
).
Operation
**Auto Tracking or Manual only on G-Flex 1500
11