Operation
close to the desired feed rate. This directly changes
the Amplitude value.
6. For fine tune adjustment, REPEATEDLY PRESS
the UP or DOWN arrow keys to dial in on the
desired feed rate. This directly changes the CFR
Value.
NOTE: This completes the typical start up and operation that should be used for most part applications. The follow-
ing section covers advanced programming operating instructions that should only be used in highly unique applica-
tions.
10
7. Once the feed rate is determined, record the CFR
value of the part for future reference on the CFR
Value table provided on page 31.
NOTE: The chart below illustrates a general rule for
operating the G-Flex 1500. Parts with less surface area
and more mass will require a greater CFR to move parts
around the table.
More
ti21920a
Mass
Less
ti21919a
CFR Value
Surface Area
Larger
ti21440a
Smaller
332462A