BLO WER DATA
SLP99UH135XV60D BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR − Air volumes in bold require Optional Return Air Base and field fabricated transition to accommodate
20 x 25 x 1 in. air filter in order to maintain proper air velocity.
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between.
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times.
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages.
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28% and 38% (DIP switch selectable) of the same second-stage COOL speed position.
minimum 380 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
35%
40%
927
1010
844
923
760
836
703
775
646
715
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
1070
1235
1385
985
1110
1245
870
1010
1110
Page 18
Heating Input Range and Blower Volume - CFM
50%
60%
1175
1340
1081
1239
987
1138
919
1064
852
989
Blower Speed Selections
High
Low
(Default)
1535
1550
1395
1415
1260
1280
70%
80%
90%
1505
1671
1836
1398
1556
1714
1290
1441
1593
1208
1352
1496
1126
1263
1400
Second Stage Cool Speed - cfm
Medium-
Medium
Low
High
1720
1925
1605
1755
1435
1610
100%
2001
1873
1744
1641
1537
High
(Default)
2005
1970
1755