BLO WER DATA
SLP99UH110XV60C BLOWER PERFORMANCE (less filter)
SINGLE SIDE RETURN AIR − Air volumes in bold require Optional Return Air Base and field fabricated transition to accommodate
20 x 25 x 1 in. air filter in order to maintain proper air velocity.
HEATING BLOWER PERFORMANCE - 0 through 0.8 in. w.g. External Static Pressure Range
Heating Adjust CFM Selections
Increase (+15%) Heat CFM
Increase (+7.5%) Heat CFM
Default Heat CFM
Decrease (-7.5% ) Heat CFM
Decrease (-15% ) Heat CFM
COOLING BLOWER PERFORMANCE - 0 through 1.0 in. w.g. External Static Pressure Range
Cooling Adjust CFM
Selections
Increase (+10%) Cool CFM
Default Cool CFM
Decrease (-10%) Cool CFM
The effect of static pressure is included in air volumes shown.
The following control configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Modes Available (Heating Blower Performance Table):
Single stage thermostat:
- 35%, 70%, 100% input (three-stage) with time delays in-between.
Two-stage thermostat:
- Variable Rate Capacity Mode - furnace automatically adjusts firing rate based on first- and second-stage cycle times.
- W1 demand at 70% input, W2 demand at 100% input. No delay between stages.
Cool Mode Available (Cooling Blower Performance table):
First stage COOL (two-stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan speeds are approximately 28% and 38% (DIP switch selectable) of the same second-stage COOL speed position.
minimum 380 cfm.
Lennox iHarmony
Zoning System Applications - Minimum blower speed is 450 cfm.
®
35%
40%
733
825
708
794
683
763
632
707
580
650
First Stage Cool Speed - cfm
Low
Medium-
Medium
Low
High
1050
1195
1315
960
1095
1220
850
985
1095
Page 16
Heating Input Range and Blower Volume - CFM
50%
60%
1009
1194
967
1139
924
1085
857
1007
790
929
Blower Speed Selections
High
Low
(Default)
1495
1515
1355
1360
1220
1215
70%
80%
90%
1378
1562
1747
1312
1484
1657
1245
1406
1566
1157
1307
1457
1069
1209
1348
Second Stage Cool Speed - cfm
Medium-
Medium
Low
High
1710
1870
1555
1755
1400
1555
100%
1931
1829
1727
1608
1488
High
(Default)
2065
1890
1755