Initial System Configuration
Enter admin status of the SCe after abnormal boot:
1- Operational
2- Not-Operational
Enter your choice [1]:
The following examples present the procedure for configuring the topology-related parameters for
various topologies. Refer the Topology Configuration Summary Table (on page 3-9) for a
summary of appropriate values for the parameters for each topology.
E
XAMPLE
Following is a sample topology configuration for a topology using an external switch.
All other parameter values are automatically assigned by the system as follows:
Link bypass mode on-failure — Bypass
•
Admin status of the SCE after abnormal boot — Operational
•
Would you like to enter the Topology configuration menu? [no]: y
Enter Connection mode:
1- inline
2- receive-only
Enter your choice [1]: 2
E
XAMPLE
Following is a sample topology configuration for a non-redundant bump-in-the-wire (inline)
topology. All values are the system default values, so it is not necessary to type in the response.
Simply press enter at each line.
Connection mode — Inline
•
For a non-redundant topology, link bypass on-failure should be Bypass, so that traffic
•
continues to flow through the link.
After operation of the system resumes, and the SCE 1000 reboots, the SCE 1000 will resume
•
operation. (Admin status after abnormal reboot is Operational.)
Would you like to enter the Topology configuration menu? [no]: y
Enter Connection mode:
1- inline
2- receive-only
Enter your choice [1]:
Enter On-failure behavior:
1- Bypass
2- Cutoff
Enter your choice [1]:
Enter admin status of the SCe after abnormal boot:
1- Operational
2- Not-Operational
Enter your choice [1]:
Data collection for the system configuration is completed.
Cisco SCE 1000 2xGBE Installation and Configuration Guide
5-20
Chapter 5
Connecting the Management Interfaces and Performing Initial System Configuration
To specify Not-Operational status after abnormal boot, press Enter.
•
•
To specify Operational status after abnormal boot, type 1 and press Enter.
1:
2:
OL-7821-05