Commissioning - Dimplex DHW 250P Installation And Operating Instructions Manual

Domestic hot water heat pump
Table of Contents

Advertisement

Available languages

Available languages

English
External control
NOTE
An external connection must be floating. Otherwise,
there is a risk that the electrical components may be
destroyed. Failure to observe these instructions will
void any warranty claims.
For access to the electrical connections:
Remove the cover of the device and remove the
fixing screw on the bottom flange for this purpose.
Remove the protective cover of the electronic
board.
EN-12

9. Commissioning

NOTE
High risk of damage: Fill the cylinder before commis-
sioning and connection to the mains.
NOTE
Before commissioning, check the entire water circuit
for leaks.
Leave the device switched off.
Open the top domestic hot water tapping point of
the
system.
Open the cold water inlet on the safety group.
Fill the cylinder until the water runs from the top
tapping point free from bubbles.
Close the domestic hot water tapping point.
In the permissible range between +5 °C and +45 °C in-
take air temperature, the device is primarily in heat
pump operation.
The domestic hot water temperature supplied by the
heat pump can be controlled up to 60 °C.
For a high domestic hot water consumption, the do-
mestic hot water heat pump has a so-called "Comfort"
function
. With this function, the heat output is in-
creased if only 1/3 of the remaining cylinder volume is
above temperatures >38 °C.
If a large quantity of domestic hot water is required for
a short time, the domestic hot water heat pump has a
"Turbo" function (can be activated by the user), which
heats up the water quickly to the desired temperature
using the supplementary electric heating (e.g. to
50 °C). This function is deactivated again as soon as
the setpoint is reached (e.g. 50 °C).
FD 0207
Commissioning
www.dimplex.de