Circuit Breaker Module - Graco Reactor A-25 Repair Parts

Air and hydraulic, heated, plural component proportioners
Hide thumbs Also See for Reactor A-25:
Table of Contents

Advertisement

Circuit Breaker Module

1. Turn main power OFF
supply.
WARNING
Read warnings, page 8.
2. Relieve pressure, page 11.
NOTE: To reference cables and con-
nectors, see the electrical diagrams and
the parts drawings on pages 51-53.
F
. 2. Circuit Breaker Module
IG
18
. Disconnect power
806
817A
804A
3. Using an ohmmeter, check for continuity across cir-
cuit breaker (top to bottom). If no continuity, trip
breaker, reset, and retest. If still no continuity,
replace breaker as follows:
a. Refer to electrical diagrams and to T
connect wires and remove bad breaker.
b. Install new breaker and reconnect wires.
Table 1: Circuit Breakers, see F
Ref. No.
Size
806
50 A
817A
20 A
804A
25 or 40 A*
804B
25 or 40 A*
817B
20 A
* Depending on model.
804B
817B
Repair
1. Dis-
ABLE
. 2
IG
Component
Hose/Transformer
Secondary Side
Transformer
Primary
Heater A
Heater B
Not Used
TI2514A
309813B

Advertisement

Table of Contents
loading

Table of Contents