Circuit Breaker Module - Graco Reactor E Series Manual

Electric, heated, plural component proportioner
Table of Contents

Advertisement

Circuit Breaker Module

1. Turn main power OFF
supply.
WARNING
Read warnings, page 5. Wait 5 min for stored voltage
to discharge (E-30 and E-XP2 models only).
2. Relieve pressure, page 8.
3. Refer to electrical diagrams and to following table.
Disconnect wires and remove bad breaker.
4. Install new breaker and reconnect wires.
NOTE: To reference cables and con-
nectors, see the electrical diagrams and
the parts drawings on pages 57-59.
F
. 6. Circuit Breaker Module
IG
26
. Disconnect power
806
817A
804A
Table 1: Circuit Breakers, see F
Ref. No.
Size
806
50 A
817A
20 A
804A
25 or 40 A*
804B
25 or 40 A*
817B
20 A
* Depending on model.
804B
817B
Repair
. 6
IG
Component
Hose/Transformer
Secondary Side
Transformer
Primary
Heater A
Heater B
Motor/Pumps
TI2514A
309574C